Address:No.9, No.12 Road, East Lianhe Industrial Zone, Luocun Town, Nanhai District, Foshan City, Guangdong Province, China. |
Liquid expansion type thermostat
First, principle & performance and application ![]()
Fourth, switch form
1. Electric property: 16 (3) A-250V~ 10 (1.8) A-400V~ 2. Break-off temperature: available temperature range (-35℃~ +320℃) according to customers’ requirement 3. Product lifetime: >100 thousand times 4. Electric strength: AC 2000V/1min 5. Normal insulation resistance: ≥100MΩ 6. Contact resistance: ≦50mΩ 7. Humidity insulation resistance: ≥10MΩ 8. Speed of temperature response≦1.0℃/min 9. Minimum current: 200mA Fourth, switch form ![]() Fifth, temperature sensor and capillary tube (design according to customers’ requirements) ![]() Six,Notice: 1. Customers can order type and size according to their products’ features and their needed temperature for control. 2. When installing thermostat, temperature sensor should closely adhere to temperature-controlled surface so as to control temperature accurately. 3. To avoid influence its performance, temperature sensor can not be deformed by press. 4. Don’t let conductive gas or material enter into thermostat or pollute its surface, which will influence electrical insulation performance. 5. M4 machine tap of installing bracket can not be overlong. Otherwise it will destroy thermostat performance. 6. As a electric ceramic part, switch box should be handled with care to avoid damage. 7. The bend radius of capillary tube should not less than 5mm. |